valve-model-2412-kofloc-vietnam-2.png
Rated flow ranges See the table below
Number of turns of regulating screw Approx. 12 turns
Maximum operating pressure 1.0 MPa
Maximum operating temperature (B) 70℃
(SS) 120℃
Materials of parts in contact with fluids (B) Brass, POM, NBR
(SS) SUS316, fluorocarbon resin, FKM
Fluids Gas and liquid
Connection end Rc 1/4 (standard)

 

Needle # Supply pressure (MPa)(Air at 20℃) Supply pressure (MPa)(Water at 20℃)
0.05 0.1 0.2 0.3 0.4 0.5 0.6 0.05 0.1 0.15
#SS1 0.023 0.047 0.078 0.11 0.15 0.19 0.22
#S1 0.08 0.11 0.2 0.27 0.34 0.4 0.47
#1 0.15 0.23 0.36 0.51 0.65 0.79 0.93 0.00145 0.0026 0.0036
#2 0.34 0.46 0.71 1.0 1.2 1.5 1.75 0.0076 0.012 0.0153
#2A 0.45 0.65 1.0 1.3 1.65 2.0 2.3 0.0132 0.0195 0.0245
#3 0.9 1.3 2.0 2.6 3.25 3.9 4.6 0.0260 0.0390 0.0510
#3A 1.25 1.9 2.75 3.65 4.5 5.3 6.4 0.0365 0.0546 0.0740
#3B 1.85 2.5 3.7 5.0 6.0 7.2 8.3 0.053 0.0760 0.0980
#4 4.3 6.2 9.0 12.0 15.0 18.3 22.0 0.124 0.188 0.234
#4A 8.0 11.0 15.0 21.0 26.0 31.0 36.0 0.228 0.336 0.417
#5 10.0 14.0 21.0 27.0 33.0 40.0 46.0 0.294 0.435 0.576
#6 22.0 31.0 45.0 60.0 75.0 92.0 105.0 0.564 0.834 1.100
#6A 30.0 41.0 60.0 80.0 100 118 138 0.774 1.190
#6B 38.0 53.0 82.0 106 135 160 185 1.280 1.950
#7 80.0 110 160 215 260 285 310 1.840 2.890
* Due to operating conditions and instrumental errors, there may be differences between the values indicated      (L/MIN)
 in the table above and those that are actually used by the customer.            
* The values shown in the table above are data for Model 2412L for illustrative purposes only. As compared with the 2412L, flows on the 2412T will
 run less smooth when the flow rate increases. It is therefore recommended that the 2412L be used for flows of 5 L/MIN or more.